# # Resource backup , created Tue Jul 12 10:06:36 CEST 2022 # #--------------------------------------------------------- # SERVER access-conf-srv/vlv1, AccessConf device declaration #--------------------------------------------------------- access-conf-srv/vlv1/DEVICE/AccessConf: "sr/vacuum/vlvbe_s1",\ "sr/vacuum/vlvfe_s1.1m",\ "sr/vacuum/vlvfe_s11.2",\ "sr/vacuum/vlvfe_s12.2",\ "sr/vacuum/vlvid_s1.1",\ "sr/vacuum/vlvinj_s12.1",\ "sr/vacuum/vlvinj_s12.2",\ "sr/vacuum/vlvsct_s1" # --- sr/vacuum/vlvbe_s1 properties sr/vacuum/vlvbe_s1->Attr_config_file: "" sr/vacuum/vlvbe_s1->Attr_config_prop: #,\ "#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\ #,\ "attr:ValveStat:0:db120:22.1:FCCVLV_BE_S1:Valvola BE_S1 aperta",\ "attr:ValveStat:1:db120:22.0:FCOVLV_BE_S1:Valvola BE_S1 chiusa",\ attr:ValveStat:2:db20:0.0:spare:spare,\ attr:ValveStat:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:ValveStat:4:db20:0.0:spare:spare,\ "attr:ValveStat:5:db20:70.5:ERR_OPN_VLV_BE_S1:Errore apertura valvola VLV_BE_S1",\ "attr:ValveStat:6:db20:70.6:ERR_CLD_VLV_BE_S1:Errore chiusura valvola VLV_BE_S1",\ "attr:ValveStat:7:db20:70.7:ERR_CONT_VLV_BE_S1:TODO(MEMCONT OK?)",\ #,\ "attr:AbiGroup:0:db20:116.7:OKINTCK_VLV_BE_S1:abilitazione apertura VLV_BE_S1",\ #,\ "attr:StatRF:0:db120:22.1:FCCVLV_BE_S1:Valvola BE_S1 aperta",\ "attr:StatRF:1:db120:22.0:FCOVLV_BE_S1:Valvola BE_S1 chiusa",\ attr:StatRF:2:db20:0.1:0:Alarm,\ attr:StatRF:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:StatRF:4:db20:102.5:0:Local,\ "attr:StatRF:5:db20:70.5:ERR_OPN_VLV_BE_S1:Errore apertura valvola VLV_BE_S1",\ "attr:StatRF:6:db20:70.6:ERR_CLD_VLV_BE_S1:Errore chiusura valvola VLV_BE_S1",\ "attr:StatRF:7:db20:70.7:ERR_CONT_VLV_BE_S1:TODO(MEMCONT OK?)",\ #,\ cmd:open:Send_cmd:105:65.6,\ cmd:close:Send_cmd:105:65.7,\ # sr/vacuum/vlvbe_s1->Cutoff_ind: 3 sr/vacuum/vlvbe_s1->Low_level_srv: "sr/interlock/plc_int" sr/vacuum/vlvbe_s1->polled_attr: valvestat,\ 1000 sr/vacuum/vlvbe_s1->__SubDevices: "sr/interlock/plc_int" # --- sr/vacuum/vlvbe_s1 attribute properties sr/vacuum/vlvbe_s1/AbiGroup->comments: "116.7 - abilitazione apertura VLV_BE_S1" sr/vacuum/vlvbe_s1/AbiGroup->labels: OKINTCK_VLV_BE_S1 sr/vacuum/vlvbe_s1/AbiGroup->positions: "sr/interlock/plc_int/db20[935]" sr/vacuum/vlvbe_s1/StatRF->comments: "22.1 - Valvola BE_S1 aperta",\ "22.0 - Valvola BE_S1 chiusa",\ "0.1 - Alarm",\ "101.5 - OPERATION",\ "102.5 - Local",\ "70.5 - Errore apertura valvola VLV_BE_S1",\ "70.6 - Errore chiusura valvola VLV_BE_S1",\ "70.7 - TODO(MEMCONT OK?)" sr/vacuum/vlvbe_s1/StatRF->labels: FCCVLV_BE_S1,\ FCOVLV_BE_S1,\ 0,\ CUTOFF_SECT6_DISABLE,\ 0,\ ERR_OPN_VLV_BE_S1,\ ERR_CLD_VLV_BE_S1,\ ERR_CONT_VLV_BE_S1 sr/vacuum/vlvbe_s1/StatRF->positions: "sr/interlock/plc_int/db120[177]",\ "sr/interlock/plc_int/db120[176]",\ "sr/interlock/plc_int/db20[1]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[821]",\ "sr/interlock/plc_int/db20[565]",\ "sr/interlock/plc_int/db20[566]",\ "sr/interlock/plc_int/db20[567]" sr/vacuum/vlvbe_s1/ValveStat->comments: "22.1 - Valvola BE_S1 aperta",\ "22.0 - Valvola BE_S1 chiusa",\ "0.0 - spare",\ "101.5 - OPERATION",\ "0.0 - spare",\ "70.5 - Errore apertura valvola VLV_BE_S1",\ "70.6 - Errore chiusura valvola VLV_BE_S1",\ "70.7 - TODO(MEMCONT OK?)" sr/vacuum/vlvbe_s1/ValveStat->labels: FCCVLV_BE_S1,\ FCOVLV_BE_S1,\ spare,\ CUTOFF_SECT6_DISABLE,\ spare,\ ERR_OPN_VLV_BE_S1,\ ERR_CLD_VLV_BE_S1,\ ERR_CONT_VLV_BE_S1 sr/vacuum/vlvbe_s1/ValveStat->positions: "sr/interlock/plc_int/db120[177]",\ "sr/interlock/plc_int/db120[176]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[565]",\ "sr/interlock/plc_int/db20[566]",\ "sr/interlock/plc_int/db20[567]" # --- sr/vacuum/vlvfe_s1.1m properties sr/vacuum/vlvfe_s1.1m->Attr_config_file: "" sr/vacuum/vlvfe_s1.1m->Attr_config_prop: #,\ "#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\ #,\ "attr:ValveStat:0:db120:22.5:FCCVLV_FE_S1_1M:Valvola FE_S1.1M aperta",\ "attr:ValveStat:1:db120:22.4:FCOVLV_FE_S1_1M:Valvola FE_S1.1M chiusa",\ attr:ValveStat:2:db20:0.0:spare:spare,\ attr:ValveStat:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:ValveStat:4:db20:0.0:spare:spare,\ "attr:ValveStat:5:db20:71.0:ERR_OPN_VLV_FE_S1_1M:Errore apertura valvola VLV_FE_S1.1M",\ "attr:ValveStat:6:db20:71.1:ERR_CLD_VLV_FE_S1_1M:Errore chiusura valvola VLV_FE_S1.1M",\ "attr:ValveStat:7:db20:71.2:ERR_CONT_VLV_FE_S1_1M:TODO(MEMCONT OK?)",\ #,\ "attr:AbiGroup:0:db20:116.6:OKINTCK_VLV_FE_S1_1M:abilitazione apertura VLV_FE_S1.1M",\ #,\ "attr:StatRF:0:db120:22.5:FCCVLV_FE_S1_1M:Valvola FE_S1.1M aperta",\ "attr:StatRF:1:db120:22.4:FCOVLV_FE_S1_1M:Valvola FE_S1.1M chiusa",\ attr:StatRF:2:db20:0.1:0:Alarm,\ attr:StatRF:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:StatRF:4:db20:102.5:0:Local,\ "attr:StatRF:5:db20:71.0:ERR_OPN_VLV_FE_S1_1M:Errore apertura valvola VLV_FE_S1.1M",\ "attr:StatRF:6:db20:71.1:ERR_CLD_VLV_FE_S1_1M:Errore chiusura valvola VLV_FE_S1.1M",\ "attr:StatRF:7:db20:71.2:ERR_CONT_VLV_FE_S1_1M:TODO(MEMCONT OK?)",\ #,\ cmd:open:Send_cmd:105:65.4,\ cmd:close:Send_cmd:105:65.5,\ # sr/vacuum/vlvfe_s1.1m->Cutoff_ind: 3 sr/vacuum/vlvfe_s1.1m->Low_level_srv: "sr/interlock/plc_int" sr/vacuum/vlvfe_s1.1m->polled_attr: valvestat,\ 1000,\ state,\ 1000 sr/vacuum/vlvfe_s1.1m->__SubDevices: "sr/interlock/plc_int" # --- sr/vacuum/vlvfe_s1.1m attribute properties sr/vacuum/vlvfe_s1.1m/AbiGroup->comments: "116.6 - abilitazione apertura VLV_FE_S1.1M" sr/vacuum/vlvfe_s1.1m/AbiGroup->labels: OKINTCK_VLV_FE_S1_1M sr/vacuum/vlvfe_s1.1m/AbiGroup->positions: "sr/interlock/plc_int/db20[934]" sr/vacuum/vlvfe_s1.1m/StatRF->comments: "22.5 - Valvola FE_S1.1M aperta",\ "22.4 - Valvola FE_S1.1M chiusa",\ "0.1 - Alarm",\ "101.5 - OPERATION",\ "102.5 - Local",\ "71.0 - Errore apertura valvola VLV_FE_S1.1M",\ "71.1 - Errore chiusura valvola VLV_FE_S1.1M",\ "71.2 - TODO(MEMCONT OK?)" sr/vacuum/vlvfe_s1.1m/StatRF->labels: FCCVLV_FE_S1_1M,\ FCOVLV_FE_S1_1M,\ 0,\ CUTOFF_SECT6_DISABLE,\ 0,\ ERR_OPN_VLV_FE_S1_1M,\ ERR_CLD_VLV_FE_S1_1M,\ ERR_CONT_VLV_FE_S1_1M sr/vacuum/vlvfe_s1.1m/StatRF->positions: "sr/interlock/plc_int/db120[181]",\ "sr/interlock/plc_int/db120[180]",\ "sr/interlock/plc_int/db20[1]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[821]",\ "sr/interlock/plc_int/db20[568]",\ "sr/interlock/plc_int/db20[569]",\ "sr/interlock/plc_int/db20[570]" sr/vacuum/vlvfe_s1.1m/ValveStat->comments: "22.5 - Valvola FE_S1.1M aperta",\ "22.4 - Valvola FE_S1.1M chiusa",\ "0.0 - spare",\ "101.5 - OPERATION",\ "0.0 - spare",\ "71.0 - Errore apertura valvola VLV_FE_S1.1M",\ "71.1 - Errore chiusura valvola VLV_FE_S1.1M",\ "71.2 - TODO(MEMCONT OK?)" sr/vacuum/vlvfe_s1.1m/ValveStat->labels: FCCVLV_FE_S1_1M,\ FCOVLV_FE_S1_1M,\ spare,\ CUTOFF_SECT6_DISABLE,\ spare,\ ERR_OPN_VLV_FE_S1_1M,\ ERR_CLD_VLV_FE_S1_1M,\ ERR_CONT_VLV_FE_S1_1M sr/vacuum/vlvfe_s1.1m/ValveStat->positions: "sr/interlock/plc_int/db120[181]",\ "sr/interlock/plc_int/db120[180]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[568]",\ "sr/interlock/plc_int/db20[569]",\ "sr/interlock/plc_int/db20[570]" # --- sr/vacuum/vlvfe_s11.2 properties sr/vacuum/vlvfe_s11.2->Attr_config_file: "" sr/vacuum/vlvfe_s11.2->Attr_config_prop: #,\ "#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\ #,\ "attr:ValveStat:0:db120:19.5:FCCVLV_FE_S11_2:Valvola FE_S11.2 aperta",\ "attr:ValveStat:1:db120:19.4:FCOVLV_FE_S11_2:Valvola FE_S11.2 chiusa",\ attr:ValveStat:2:db20:0.0:spare:spare,\ attr:ValveStat:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:ValveStat:4:db20:0.0:spare:spare,\ "attr:ValveStat:5:db20:68.6:ERR_OPN_VLV_FE_S11_2:Errore apertura valvola VLV_FE_S11.2",\ "attr:ValveStat:6:db20:68.7:ERR_CLD_VLV_FE_S11_2:Errore chiusura valvola VLV_FE_S11.2",\ "attr:ValveStat:7:db20:69.0:ERR_CONT_VLV_FE_S11_2:TODO(MEMCONT OK?)",\ #,\ "attr:AbiGroup:0:db20:116.2:OKINTCK_VLV_FE_S11_2:abilitazione apertura VLV_FE_S11.2",\ #,\ "attr:StatRF:0:db120:19.5:FCCVLV_FE_S11_2:Valvola FE_S11.2 aperta",\ "attr:StatRF:1:db120:19.4:FCOVLV_FE_S11_2:Valvola FE_S11.2 chiusa",\ attr:StatRF:2:db20:0.1:0:Alarm,\ attr:StatRF:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:StatRF:4:db20:102.5:0:Local,\ "attr:StatRF:5:db20:68.6:ERR_OPN_VLV_FE_S11_2:Errore apertura valvola VLV_FE_S11.2",\ "attr:StatRF:6:db20:68.7:ERR_CLD_VLV_FE_S11_2:Errore chiusura valvola VLV_FE_S11.2",\ "attr:StatRF:7:db20:69.0:ERR_CONT_VLV_FE_S11_2:TODO(MEMCONT OK?)",\ #,\ cmd:open:Send_cmd:105:64.4,\ cmd:close:Send_cmd:105:64.5,\ # sr/vacuum/vlvfe_s11.2->Cutoff_ind: 3 sr/vacuum/vlvfe_s11.2->Low_level_srv: "sr/interlock/plc_int" sr/vacuum/vlvfe_s11.2->polled_attr: valvestat,\ 1000,\ state,\ 1000 sr/vacuum/vlvfe_s11.2->__SubDevices: "sr/interlock/plc_int" # --- sr/vacuum/vlvfe_s11.2 attribute properties sr/vacuum/vlvfe_s11.2/AbiGroup->comments: "116.2 - abilitazione apertura VLV_FE_S11.2" sr/vacuum/vlvfe_s11.2/AbiGroup->labels: OKINTCK_VLV_FE_S11_2 sr/vacuum/vlvfe_s11.2/AbiGroup->positions: "sr/interlock/plc_int/db20[930]" sr/vacuum/vlvfe_s11.2/StatRF->comments: "19.5 - Valvola FE_S11.2 aperta",\ "19.4 - Valvola FE_S11.2 chiusa",\ "0.1 - Alarm",\ "101.5 - OPERATION",\ "102.5 - Local",\ "68.6 - Errore apertura valvola VLV_FE_S11.2",\ "68.7 - Errore chiusura valvola VLV_FE_S11.2",\ "69.0 - TODO(MEMCONT OK?)" sr/vacuum/vlvfe_s11.2/StatRF->labels: FCCVLV_FE_S11_2,\ FCOVLV_FE_S11_2,\ 0,\ CUTOFF_SECT6_DISABLE,\ 0,\ ERR_OPN_VLV_FE_S11_2,\ ERR_CLD_VLV_FE_S11_2,\ ERR_CONT_VLV_FE_S11_2 sr/vacuum/vlvfe_s11.2/StatRF->positions: "sr/interlock/plc_int/db120[157]",\ "sr/interlock/plc_int/db120[156]",\ "sr/interlock/plc_int/db20[1]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[821]",\ "sr/interlock/plc_int/db20[550]",\ "sr/interlock/plc_int/db20[551]",\ "sr/interlock/plc_int/db20[552]" sr/vacuum/vlvfe_s11.2/ValveStat->comments: "19.5 - Valvola FE_S11.2 aperta",\ "19.4 - Valvola FE_S11.2 chiusa",\ "0.0 - spare",\ "101.5 - OPERATION",\ "0.0 - spare",\ "68.6 - Errore apertura valvola VLV_FE_S11.2",\ "68.7 - Errore chiusura valvola VLV_FE_S11.2",\ "69.0 - TODO(MEMCONT OK?)" sr/vacuum/vlvfe_s11.2/ValveStat->labels: FCCVLV_FE_S11_2,\ FCOVLV_FE_S11_2,\ spare,\ CUTOFF_SECT6_DISABLE,\ spare,\ ERR_OPN_VLV_FE_S11_2,\ ERR_CLD_VLV_FE_S11_2,\ ERR_CONT_VLV_FE_S11_2 sr/vacuum/vlvfe_s11.2/ValveStat->positions: "sr/interlock/plc_int/db120[157]",\ "sr/interlock/plc_int/db120[156]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[550]",\ "sr/interlock/plc_int/db20[551]",\ "sr/interlock/plc_int/db20[552]" # --- sr/vacuum/vlvfe_s12.2 properties sr/vacuum/vlvfe_s12.2->Attr_config_file: "" sr/vacuum/vlvfe_s12.2->Attr_config_prop: #,\ "#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\ #,\ "attr:ValveStat:0:db120:20.5:FCCVLV_FE_S12_2:Valvola FE_S12.2 aperta",\ "attr:ValveStat:1:db120:20.4:FCOVLV_FE_S12_2:Valvola FE_S12.2 chiusa",\ attr:ValveStat:2:db20:0.0:spare:spare,\ attr:ValveStat:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:ValveStat:4:db20:0.0:spare:spare,\ "attr:ValveStat:5:db20:69.4:ERR_OPN_VLV_FE_S12_2:Errore apertura valvola VLV_FE_S12.2",\ "attr:ValveStat:6:db20:69.5:ERR_CLD_VLV_FE_S12_2:Errore chiusura valvola VLV_FE_S12.2",\ "attr:ValveStat:7:db20:69.6:ERR_CONT_VLV_FE_S12_2:TODO(MEMCONT OK?)",\ #,\ "attr:AbiGroup:0:db20:116.4:OKINTCK_VLV_FE_S12_2:abilitazione apertura VLV_FE_S12.2",\ #,\ "attr:StatRF:0:db120:20.5:FCCVLV_FE_S12_2:Valvola FE_S12.2 aperta",\ "attr:StatRF:1:db120:20.4:FCOVLV_FE_S12_2:Valvola FE_S12.2 chiusa",\ attr:StatRF:2:db20:0.1:0:Alarm,\ attr:StatRF:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:StatRF:4:db20:102.5:0:Local,\ "attr:StatRF:5:db20:69.4:ERR_OPN_VLV_FE_S12_2:Errore apertura valvola VLV_FE_S12.2",\ "attr:StatRF:6:db20:69.5:ERR_CLD_VLV_FE_S12_2:Errore chiusura valvola VLV_FE_S12.2",\ "attr:StatRF:7:db20:69.6:ERR_CONT_VLV_FE_S12_2:TODO(MEMCONT OK?)",\ #,\ cmd:open:Send_cmd:105:65.0,\ cmd:close:Send_cmd:105:65.1,\ # sr/vacuum/vlvfe_s12.2->Cutoff_ind: 3 sr/vacuum/vlvfe_s12.2->Low_level_srv: "sr/interlock/plc_int" sr/vacuum/vlvfe_s12.2->polled_attr: valvestat,\ 1000,\ state,\ 1000 sr/vacuum/vlvfe_s12.2->__SubDevices: "sr/interlock/plc_int" # --- sr/vacuum/vlvfe_s12.2 attribute properties sr/vacuum/vlvfe_s12.2/AbiGroup->comments: "116.4 - abilitazione apertura VLV_FE_S12.2" sr/vacuum/vlvfe_s12.2/AbiGroup->labels: OKINTCK_VLV_FE_S12_2 sr/vacuum/vlvfe_s12.2/AbiGroup->positions: "sr/interlock/plc_int/db20[932]" sr/vacuum/vlvfe_s12.2/StatRF->comments: "20.5 - Valvola FE_S12.2 aperta",\ "20.4 - Valvola FE_S12.2 chiusa",\ "0.1 - Alarm",\ "101.5 - OPERATION",\ "102.5 - Local",\ "69.4 - Errore apertura valvola VLV_FE_S12.2",\ "69.5 - Errore chiusura valvola VLV_FE_S12.2",\ "69.6 - TODO(MEMCONT OK?)" sr/vacuum/vlvfe_s12.2/StatRF->labels: FCCVLV_FE_S12_2,\ FCOVLV_FE_S12_2,\ 0,\ CUTOFF_SECT6_DISABLE,\ 0,\ ERR_OPN_VLV_FE_S12_2,\ ERR_CLD_VLV_FE_S12_2,\ ERR_CONT_VLV_FE_S12_2 sr/vacuum/vlvfe_s12.2/StatRF->positions: "sr/interlock/plc_int/db120[165]",\ "sr/interlock/plc_int/db120[164]",\ "sr/interlock/plc_int/db20[1]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[821]",\ "sr/interlock/plc_int/db20[556]",\ "sr/interlock/plc_int/db20[557]",\ "sr/interlock/plc_int/db20[558]" sr/vacuum/vlvfe_s12.2/ValveStat->comments: "20.5 - Valvola FE_S12.2 aperta",\ "20.4 - Valvola FE_S12.2 chiusa",\ "0.0 - spare",\ "101.5 - OPERATION",\ "0.0 - spare",\ "69.4 - Errore apertura valvola VLV_FE_S12.2",\ "69.5 - Errore chiusura valvola VLV_FE_S12.2",\ "69.6 - TODO(MEMCONT OK?)" sr/vacuum/vlvfe_s12.2/ValveStat->labels: FCCVLV_FE_S12_2,\ FCOVLV_FE_S12_2,\ spare,\ CUTOFF_SECT6_DISABLE,\ spare,\ ERR_OPN_VLV_FE_S12_2,\ ERR_CLD_VLV_FE_S12_2,\ ERR_CONT_VLV_FE_S12_2 sr/vacuum/vlvfe_s12.2/ValveStat->positions: "sr/interlock/plc_int/db120[165]",\ "sr/interlock/plc_int/db120[164]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[556]",\ "sr/interlock/plc_int/db20[557]",\ "sr/interlock/plc_int/db20[558]" # --- sr/vacuum/vlvid_s1.1 properties sr/vacuum/vlvid_s1.1->Attr_config_file: "" sr/vacuum/vlvid_s1.1->Attr_config_prop: #,\ "#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\ #,\ "attr:ValveStat:0:db120:21.1:FCCVLV_ID_S1_1:Valvola ID_S1.1 aperta",\ "attr:ValveStat:1:db120:21.0:FCOVLV_ID_S1_1:Valvola ID_S1.1 chiusa",\ attr:ValveStat:2:db20:0.0:spare:spare,\ attr:ValveStat:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:ValveStat:4:db20:0.0:spare:spare,\ "attr:ValveStat:5:db20:69.7:ERR_OPN_VLV_ID_S1_1:Errore apertura valvola VLV_ID_S1.1",\ "attr:ValveStat:6:db20:70.0:ERR_CLD_VLV_ID_S1_1:Errore chiusura valvola VLV_ID_S1.1",\ "attr:ValveStat:7:db20:70.1:ERR_CONT_VLV_ID_S1_1:TODO(MEMCONT OK?)",\ #,\ "attr:AbiGroup:0:db20:117.2:OKINTCK_VLV_ID_S1:abilitazione apertura VLV_ID_S1.1",\ #,\ "attr:StatRF:0:db120:21.1:FCCVLV_ID_S1_1:Valvola ID_S1.1 aperta",\ "attr:StatRF:1:db120:21.0:FCOVLV_ID_S1_1:Valvola ID_S1.1 chiusa",\ attr:StatRF:2:db20:0.1:0:Alarm,\ attr:StatRF:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:StatRF:4:db20:102.5:0:Local,\ "attr:StatRF:5:db20:69.7:ERR_OPN_VLV_ID_S1_1:Errore apertura valvola VLV_ID_S1.1",\ "attr:StatRF:6:db20:70.0:ERR_CLD_VLV_ID_S1_1:Errore chiusura valvola VLV_ID_S1.1",\ "attr:StatRF:7:db20:70.1:ERR_CONT_VLV_ID_S1_1:TODO(MEMCONT OK?)",\ #,\ cmd:open:Send_cmd:105:66.4,\ cmd:close:Send_cmd:105:66.5,\ # sr/vacuum/vlvid_s1.1->Cutoff_ind: 3 sr/vacuum/vlvid_s1.1->Low_level_srv: "sr/interlock/plc_int" sr/vacuum/vlvid_s1.1->polled_attr: valvestat,\ 1000 sr/vacuum/vlvid_s1.1->__SubDevices: "sr/interlock/plc_int" # --- sr/vacuum/vlvid_s1.1 attribute properties sr/vacuum/vlvid_s1.1/AbiGroup->comments: "117.2 - abilitazione apertura VLV_ID_S1.1" sr/vacuum/vlvid_s1.1/AbiGroup->labels: OKINTCK_VLV_ID_S1 sr/vacuum/vlvid_s1.1/AbiGroup->positions: "sr/interlock/plc_int/db20[938]" sr/vacuum/vlvid_s1.1/StatRF->comments: "21.1 - Valvola ID_S1.1 aperta",\ "21.0 - Valvola ID_S1.1 chiusa",\ "0.1 - Alarm",\ "101.5 - OPERATION",\ "102.5 - Local",\ "69.7 - Errore apertura valvola VLV_ID_S1.1",\ "70.0 - Errore chiusura valvola VLV_ID_S1.1",\ "70.1 - TODO(MEMCONT OK?)" sr/vacuum/vlvid_s1.1/StatRF->labels: FCCVLV_ID_S1_1,\ FCOVLV_ID_S1_1,\ 0,\ CUTOFF_SECT6_DISABLE,\ 0,\ ERR_OPN_VLV_ID_S1_1,\ ERR_CLD_VLV_ID_S1_1,\ ERR_CONT_VLV_ID_S1_1 sr/vacuum/vlvid_s1.1/StatRF->positions: "sr/interlock/plc_int/db120[169]",\ "sr/interlock/plc_int/db120[168]",\ "sr/interlock/plc_int/db20[1]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[821]",\ "sr/interlock/plc_int/db20[559]",\ "sr/interlock/plc_int/db20[560]",\ "sr/interlock/plc_int/db20[561]" sr/vacuum/vlvid_s1.1/ValveStat->comments: "21.1 - Valvola ID_S1.1 aperta",\ "21.0 - Valvola ID_S1.1 chiusa",\ "0.0 - spare",\ "101.5 - OPERATION",\ "0.0 - spare",\ "69.7 - Errore apertura valvola VLV_ID_S1.1",\ "70.0 - Errore chiusura valvola VLV_ID_S1.1",\ "70.1 - TODO(MEMCONT OK?)" sr/vacuum/vlvid_s1.1/ValveStat->labels: FCCVLV_ID_S1_1,\ FCOVLV_ID_S1_1,\ spare,\ CUTOFF_SECT6_DISABLE,\ spare,\ ERR_OPN_VLV_ID_S1_1,\ ERR_CLD_VLV_ID_S1_1,\ ERR_CONT_VLV_ID_S1_1 sr/vacuum/vlvid_s1.1/ValveStat->positions: "sr/interlock/plc_int/db120[169]",\ "sr/interlock/plc_int/db120[168]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[559]",\ "sr/interlock/plc_int/db20[560]",\ "sr/interlock/plc_int/db20[561]" # --- sr/vacuum/vlvinj_s12.1 properties sr/vacuum/vlvinj_s12.1->Attr_config_file: "" sr/vacuum/vlvinj_s12.1->Attr_config_prop: #,\ "#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\ #,\ "attr:ValveStat:0:db120:23.1:FCCVLV_INJ_S12_1:Valvola INJ_S12.1 aperta",\ "attr:ValveStat:1:db120:23.0:FCOVLV_INJ_S12_1:Valvola INJ_S12.1 chiusa",\ attr:ValveStat:2:db20:0.0:spare:spare,\ attr:ValveStat:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:ValveStat:4:db20:0.0:spare:spare,\ "attr:ValveStat:5:db20:71.3:ERR_OPN_VLV_INJ_S12_1:Errore apertura valvola VLV_INJ_S12.1",\ "attr:ValveStat:6:db20:71.4:ERR_CLD_VLV_INJ_S12_1:Errore chiusura valvola VLV_INJ_S12.1",\ "attr:ValveStat:7:db20:71.5:ERR_CONT_VLV_INJ_S12_1:TODO(MEMCONT OK?)",\ #,\ "attr:AbiGroup:0:db20:117.0:OKINTCK_VLV_INJ_S12_1:abilitazione apertura VLV_INJ_S12.1",\ #,\ "attr:StatRF:0:db120:23.1:FCCVLV_INJ_S12_1:Valvola INJ_S12.1 aperta",\ "attr:StatRF:1:db120:23.0:FCOVLV_INJ_S12_1:Valvola INJ_S12.1 chiusa",\ attr:StatRF:2:db20:0.1:0:Alarm,\ attr:StatRF:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:StatRF:4:db20:102.5:0:Local,\ "attr:StatRF:5:db20:71.3:ERR_OPN_VLV_INJ_S12_1:Errore apertura valvola VLV_INJ_S12.1",\ "attr:StatRF:6:db20:71.4:ERR_CLD_VLV_INJ_S12_1:Errore chiusura valvola VLV_INJ_S12.1",\ "attr:StatRF:7:db20:71.5:ERR_CONT_VLV_INJ_S12_1:TODO(MEMCONT OK?)",\ #,\ cmd:open:Send_cmd:105:66.0,\ cmd:close:Send_cmd:105:66.1,\ # sr/vacuum/vlvinj_s12.1->Cutoff_ind: 3 sr/vacuum/vlvinj_s12.1->Low_level_srv: "sr/interlock/plc_int" sr/vacuum/vlvinj_s12.1->polled_attr: valvestat,\ 1000 sr/vacuum/vlvinj_s12.1->__SubDevices: "sr/interlock/plc_int" # --- sr/vacuum/vlvinj_s12.1 attribute properties sr/vacuum/vlvinj_s12.1/AbiGroup->comments: "117.0 - abilitazione apertura VLV_INJ_S12.1" sr/vacuum/vlvinj_s12.1/AbiGroup->labels: OKINTCK_VLV_INJ_S12_1 sr/vacuum/vlvinj_s12.1/AbiGroup->positions: "sr/interlock/plc_int/db20[936]" sr/vacuum/vlvinj_s12.1/StatRF->comments: "23.1 - Valvola INJ_S12.1 aperta",\ "23.0 - Valvola INJ_S12.1 chiusa",\ "0.1 - Alarm",\ "101.5 - OPERATION",\ "102.5 - Local",\ "71.3 - Errore apertura valvola VLV_INJ_S12.1",\ "71.4 - Errore chiusura valvola VLV_INJ_S12.1",\ "71.5 - TODO(MEMCONT OK?)" sr/vacuum/vlvinj_s12.1/StatRF->labels: FCCVLV_INJ_S12_1,\ FCOVLV_INJ_S12_1,\ 0,\ CUTOFF_SECT6_DISABLE,\ 0,\ ERR_OPN_VLV_INJ_S12_1,\ ERR_CLD_VLV_INJ_S12_1,\ ERR_CONT_VLV_INJ_S12_1 sr/vacuum/vlvinj_s12.1/StatRF->positions: "sr/interlock/plc_int/db120[185]",\ "sr/interlock/plc_int/db120[184]",\ "sr/interlock/plc_int/db20[1]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[821]",\ "sr/interlock/plc_int/db20[571]",\ "sr/interlock/plc_int/db20[572]",\ "sr/interlock/plc_int/db20[573]" sr/vacuum/vlvinj_s12.1/ValveStat->comments: "23.1 - Valvola INJ_S12.1 aperta",\ "23.0 - Valvola INJ_S12.1 chiusa",\ "0.0 - spare",\ "101.5 - OPERATION",\ "0.0 - spare",\ "71.3 - Errore apertura valvola VLV_INJ_S12.1",\ "71.4 - Errore chiusura valvola VLV_INJ_S12.1",\ "71.5 - TODO(MEMCONT OK?)" sr/vacuum/vlvinj_s12.1/ValveStat->labels: FCCVLV_INJ_S12_1,\ FCOVLV_INJ_S12_1,\ spare,\ CUTOFF_SECT6_DISABLE,\ spare,\ ERR_OPN_VLV_INJ_S12_1,\ ERR_CLD_VLV_INJ_S12_1,\ ERR_CONT_VLV_INJ_S12_1 sr/vacuum/vlvinj_s12.1/ValveStat->positions: "sr/interlock/plc_int/db120[185]",\ "sr/interlock/plc_int/db120[184]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[571]",\ "sr/interlock/plc_int/db20[572]",\ "sr/interlock/plc_int/db20[573]" # --- sr/vacuum/vlvinj_s12.2 properties sr/vacuum/vlvinj_s12.2->Attr_config_file: "" sr/vacuum/vlvinj_s12.2->Attr_config_prop: #,\ "#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\ #,\ "attr:ValveStat:0:db120:23.5:FCCVLV_INJ_S12_2:Valvola INJ_S12.2 aperta",\ "attr:ValveStat:1:db120:23.4:FCOVLV_INJ_S12_2:Valvola INJ_S12.2 chiusa",\ attr:ValveStat:2:db20:0.0:spare:spare,\ attr:ValveStat:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:ValveStat:4:db20:0.0:spare:spare,\ "attr:ValveStat:5:db20:71.6:ERR_OPN_VLV_INJ_S12_2:Errore apertura valvola VLV_INJ_S12.2",\ "attr:ValveStat:6:db20:71.7:ERR_CLD_VLV_INJ_S12_2:Errore chiusura valvola VLV_INJ_S12.2",\ "attr:ValveStat:7:db20:72.0:ERR_CONT_VLV_INJ_S12_2:TODO(MEMCONT OK?)",\ #,\ "attr:AbiGroup:0:db20:117.1:OKINTCK_VLV_INJ_S12_2:abilitazione apertura VLV_INJ_S12.2",\ #,\ "attr:StatRF:0:db120:23.5:FCCVLV_INJ_S12_2:Valvola INJ_S12.2 aperta",\ "attr:StatRF:1:db120:23.4:FCOVLV_INJ_S12_2:Valvola INJ_S12.2 chiusa",\ attr:StatRF:2:db20:0.1:0:Alarm,\ attr:StatRF:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:StatRF:4:db20:102.5:0:Local,\ "attr:StatRF:5:db20:71.6:ERR_OPN_VLV_INJ_S12_2:Errore apertura valvola VLV_INJ_S12.2",\ "attr:StatRF:6:db20:71.7:ERR_CLD_VLV_INJ_S12_2:Errore chiusura valvola VLV_INJ_S12.2",\ "attr:StatRF:7:db20:72.0:ERR_CONT_VLV_INJ_S12_2:TODO(MEMCONT OK?)",\ #,\ cmd:open:Send_cmd:105:66.2,\ cmd:close:Send_cmd:105:66.3,\ # sr/vacuum/vlvinj_s12.2->Cutoff_ind: 3 sr/vacuum/vlvinj_s12.2->Low_level_srv: "sr/interlock/plc_int" sr/vacuum/vlvinj_s12.2->polled_attr: valvestat,\ 1000 sr/vacuum/vlvinj_s12.2->__SubDevices: "sr/interlock/plc_int" # --- sr/vacuum/vlvinj_s12.2 attribute properties sr/vacuum/vlvinj_s12.2/AbiGroup->comments: "117.1 - abilitazione apertura VLV_INJ_S12.2" sr/vacuum/vlvinj_s12.2/AbiGroup->labels: OKINTCK_VLV_INJ_S12_2 sr/vacuum/vlvinj_s12.2/AbiGroup->positions: "sr/interlock/plc_int/db20[937]" sr/vacuum/vlvinj_s12.2/StatRF->comments: "23.5 - Valvola INJ_S12.2 aperta",\ "23.4 - Valvola INJ_S12.2 chiusa",\ "0.1 - Alarm",\ "101.5 - OPERATION",\ "102.5 - Local",\ "71.6 - Errore apertura valvola VLV_INJ_S12.2",\ "71.7 - Errore chiusura valvola VLV_INJ_S12.2",\ "72.0 - TODO(MEMCONT OK?)" sr/vacuum/vlvinj_s12.2/StatRF->labels: FCCVLV_INJ_S12_2,\ FCOVLV_INJ_S12_2,\ 0,\ CUTOFF_SECT6_DISABLE,\ 0,\ ERR_OPN_VLV_INJ_S12_2,\ ERR_CLD_VLV_INJ_S12_2,\ ERR_CONT_VLV_INJ_S12_2 sr/vacuum/vlvinj_s12.2/StatRF->positions: "sr/interlock/plc_int/db120[189]",\ "sr/interlock/plc_int/db120[188]",\ "sr/interlock/plc_int/db20[1]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[821]",\ "sr/interlock/plc_int/db20[574]",\ "sr/interlock/plc_int/db20[575]",\ "sr/interlock/plc_int/db20[576]" sr/vacuum/vlvinj_s12.2/ValveStat->comments: "23.5 - Valvola INJ_S12.2 aperta",\ "23.4 - Valvola INJ_S12.2 chiusa",\ "0.0 - spare",\ "101.5 - OPERATION",\ "0.0 - spare",\ "71.6 - Errore apertura valvola VLV_INJ_S12.2",\ "71.7 - Errore chiusura valvola VLV_INJ_S12.2",\ "72.0 - TODO(MEMCONT OK?)" sr/vacuum/vlvinj_s12.2/ValveStat->labels: FCCVLV_INJ_S12_2,\ FCOVLV_INJ_S12_2,\ spare,\ CUTOFF_SECT6_DISABLE,\ spare,\ ERR_OPN_VLV_INJ_S12_2,\ ERR_CLD_VLV_INJ_S12_2,\ ERR_CONT_VLV_INJ_S12_2 sr/vacuum/vlvinj_s12.2/ValveStat->positions: "sr/interlock/plc_int/db120[189]",\ "sr/interlock/plc_int/db120[188]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[574]",\ "sr/interlock/plc_int/db20[575]",\ "sr/interlock/plc_int/db20[576]" # --- sr/vacuum/vlvsct_s1 properties sr/vacuum/vlvsct_s1->Attr_config_file: "" sr/vacuum/vlvsct_s1->Attr_config_prop: #,\ "#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\ #,\ "attr:ValveStat:0:db120:21.5:FCCVLV_SCT_S1:Valvola SCT_S1 aperta",\ "attr:ValveStat:1:db120:21.4:FCOVLV_SCT_S1:Valvola SCT_S1 chiusa",\ attr:ValveStat:2:db20:0.0:spare:spare,\ attr:ValveStat:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:ValveStat:4:db20:0.0:spare:spare,\ "attr:ValveStat:5:db20:70.2:ERR_OPN_VLV_SCT_S1:Errore apertura valvola VLV_SCT_S1",\ "attr:ValveStat:6:db20:70.3:ERR_CLD_VLV_SCT_S1:Errore chiusura valvola VLV_SCT_S1",\ "attr:ValveStat:7:db20:70.4:ERR_CONT_VLV_SCT_S1:TODO(MEMCONT OK?)",\ #,\ "attr:AbiGroup:0:db20:110.4:OKINTCK_VLV_SCT_S1:abilitazione apertura VLV_SCT_S1",\ #,\ "attr:StatRF:0:db120:21.5:FCCVLV_SCT_S1:Valvola SCT_S1 aperta",\ "attr:StatRF:1:db120:21.4:FCOVLV_SCT_S1:Valvola SCT_S1 chiusa",\ attr:StatRF:2:db20:0.0:0:Alarm,\ attr:StatRF:3:db20:101.5:CUTOFF_SECT6_DISABLE:OPERATION,\ attr:StatRF:4:db20:102.5:0:Local,\ "attr:StatRF:5:db20:70.2:ERR_OPN_VLV_SCT_S1:Errore apertura valvola VLV_SCT_S1",\ "attr:StatRF:6:db20:70.3:ERR_CLD_VLV_SCT_S1:Errore chiusura valvola VLV_SCT_S1",\ "attr:StatRF:7:db20:70.4:ERR_CONT_VLV_SCT_S1:TODO(MEMCONT OK?)",\ #,\ cmd:open:Send_cmd:105:53.0,\ cmd:close:Send_cmd:105:53.1,\ # sr/vacuum/vlvsct_s1->Cutoff_ind: 3 sr/vacuum/vlvsct_s1->Low_level_srv: "sr/interlock/plc_int" sr/vacuum/vlvsct_s1->polled_attr: valvestat,\ 1000 sr/vacuum/vlvsct_s1->__SubDevices: "sr/interlock/plc_int" # --- sr/vacuum/vlvsct_s1 attribute properties sr/vacuum/vlvsct_s1/AbiGroup->comments: "110.4 - abilitazione apertura VLV_SCT_S1" sr/vacuum/vlvsct_s1/AbiGroup->labels: OKINTCK_VLV_SCT_S1 sr/vacuum/vlvsct_s1/AbiGroup->positions: "sr/interlock/plc_int/db20[884]" sr/vacuum/vlvsct_s1/StatRF->comments: "21.5 - Valvola SCT_S1 aperta",\ "21.4 - Valvola SCT_S1 chiusa",\ "0.0 - Alarm",\ "101.5 - OPERATION",\ "102.5 - Local",\ "70.2 - Errore apertura valvola VLV_SCT_S1",\ "70.3 - Errore chiusura valvola VLV_SCT_S1",\ "70.4 - TODO(MEMCONT OK?)" sr/vacuum/vlvsct_s1/StatRF->labels: FCCVLV_SCT_S1,\ FCOVLV_SCT_S1,\ 0,\ CUTOFF_SECT6_DISABLE,\ 0,\ ERR_OPN_VLV_SCT_S1,\ ERR_CLD_VLV_SCT_S1,\ ERR_CONT_VLV_SCT_S1 sr/vacuum/vlvsct_s1/StatRF->positions: "sr/interlock/plc_int/db120[173]",\ "sr/interlock/plc_int/db120[172]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[821]",\ "sr/interlock/plc_int/db20[562]",\ "sr/interlock/plc_int/db20[563]",\ "sr/interlock/plc_int/db20[564]" sr/vacuum/vlvsct_s1/ValveStat->comments: "21.5 - Valvola SCT_S1 aperta",\ "21.4 - Valvola SCT_S1 chiusa",\ "0.0 - spare",\ "101.5 - OPERATION",\ "0.0 - spare",\ "70.2 - Errore apertura valvola VLV_SCT_S1",\ "70.3 - Errore chiusura valvola VLV_SCT_S1",\ "70.4 - TODO(MEMCONT OK?)" sr/vacuum/vlvsct_s1/ValveStat->labels: FCCVLV_SCT_S1,\ FCOVLV_SCT_S1,\ spare,\ CUTOFF_SECT6_DISABLE,\ spare,\ ERR_OPN_VLV_SCT_S1,\ ERR_CLD_VLV_SCT_S1,\ ERR_CONT_VLV_SCT_S1 sr/vacuum/vlvsct_s1/ValveStat->positions: "sr/interlock/plc_int/db120[173]",\ "sr/interlock/plc_int/db120[172]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[813]",\ "sr/interlock/plc_int/db20[0]",\ "sr/interlock/plc_int/db20[562]",\ "sr/interlock/plc_int/db20[563]",\ "sr/interlock/plc_int/db20[564]" #--------------------------------------------------------- # CLASS AccessConf properties #--------------------------------------------------------- CLASS/AccessConf->cvs_location: "/home/cvsadm/cvsroot/fermi/servers/accessconf/src/" CLASS/AccessConf->cvs_tag: release_12 CLASS/AccessConf->Description: "" CLASS/AccessConf->doc_url: "http://www.esrf.eu/computing/cs/tango/tango_doc/ds_doc/" CLASS/AccessConf->InheritedFrom: Device_Impl CLASS/AccessConf->ProjectTitle: "Storage Ring Access" # CLASS AccessConf attribute properties # --- dserver/access-conf-srv/vlv1 properties dserver/access-conf-srv/vlv1->polling_threads_pool_conf: "sr/vacuum/vlvbe_s1,sr/vacuum/vlvfe_s1.1m,sr/vacuum/vlvfe_s11.2,sr/vacuum/vlvfe_s12.2,sr/vacuum/vlvid_s1.1,sr/vacuum/vlvinj_s12.1,sr/vacuum/vlvinj_s12.2,sr/vacuum/vlvsct_s1" dserver/access-conf-srv/vlv1->__SubDevices: "dserver/plcint-e-srv/sr"