Skip to content
Snippets Groups Projects
Commit b753c0a3 authored by Claudio Scafuri's avatar Claudio Scafuri :speech_balloon:
Browse files

added configurations

parent 43791b34
No related branches found
No related tags found
No related merge requests found
This diff is collapsed.
#
# Resource backup , created Fri May 22 14:01:14 CEST 2020
#
#---------------------------------------------------------
# SERVER accessconf-srv/booster, AccessConf device declaration
#---------------------------------------------------------
access-conf-srv/booster/DEVICE/AccessConf: "booster/interlock/bst_bts2.1"
# --- booster/interlock/bst_bts2.1 properties
booster/interlock/bst_bts2.1->Attr_config_file: ""
booster/interlock/bst_bts2.1->Attr_config_prop: #,\
"#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\
#,\
"attr:ValveStat:0:db_50:133.7:FCA_BST2_1_da_acc:Beam stopper 2.1 aperto",\
"attr:ValveStat:1:db_50:133.6:FCC_BST2_1_da_acc:Beam stopper 2.1 chiuso",\
attr:ValveStat:2:db_50:133.5:PRS_BST2.1:PRS_BST2.1,\
attr:ValveStat:3:db_50:152.4:ABI_OPN_BST2_1:ABI_OPN_BST2_1,\
attr:ValveStat:4:db_50:0.0:unused:unused,\
"attr:ValveStat:5:db_50:152.5:ERROROPEN_BST_BTS2_1:Errore apertura beam stopper BST_2_1",\
"attr:ValveStat:6:db_50:152.6:ERRORCLOSE_BST_BTS2_1_1:Errore chiusira beam stopper BST_2_1",\
attr:ValveStat:7:db_50:152.7:MEMCONT_BST_BTS2_1:MEMCONT_BST_BTS2_1,\
#,\
attr:AbiGroup:0:db_50:152.4:ABI_OPN_BST2_1:ABI_OPN_BST2_1,\
#,\
"attr:StatRF:0:db_50:133.7:FCA_BST2_1_da_acc:Beam stopper 2.1 aperto",\
"attr:StatRF:1:db_50:133.6:FCC_BST2_1_da_acc:Beam stopper 2.1 chiuso",\
attr:StatRF:2:db_50:0.1:0:Alarm,\
"attr:StatRF:3:db_50:1.2:1:Ext. supply off",\
attr:StatRF:4:db_50:0.1:0:Local,\
attr:StatRF:5:db_50:0.1:0:spare,\
attr:StatRF:6:db_50:0.1:0:spare,\
attr:StatRF:7:db_50:0.1:0:spare,\
#,\
cmd:open:Send_cmd:101:11.2,\
cmd:close:Send_cmd:101:11.3,\
#
booster/interlock/bst_bts2.1->Cutoff_ind: -1
booster/interlock/bst_bts2.1->Low_level_srv: "tom:20000/booster/interlock/plc_int"
booster/interlock/bst_bts2.1->polled_attr: state,\
2000,\
valvestat,\
2000
booster/interlock/bst_bts2.1->__SubDevices: "booster/interlock/plc_int",\
"dserver/plcint-e-srv/booster"
# --- booster/interlock/bst_bts2.1 attribute properties
booster/interlock/bst_bts2.1/AbiGroup->comments: "152.4 - ABI_OPN_BST2_1"
booster/interlock/bst_bts2.1/AbiGroup->labels: ABI_OPN_BST2_1
booster/interlock/bst_bts2.1/AbiGroup->positions: "booster/interlock/plc_int/db_50[1220]"
booster/interlock/bst_bts2.1/StatRF->comments: "133.7 - Beam stopper 2.1 aperto",\
"133.6 - Beam stopper 2.1 chiuso",\
"0.1 - Alarm",\
"1.2 - Ext. supply off",\
"0.1 - Local",\
"0.1 - spare",\
"0.1 - spare",\
"0.1 - spare"
booster/interlock/bst_bts2.1/StatRF->labels: FCA_BST2_1_da_acc,\
FCC_BST2_1_da_acc,\
0,\
1,\
0,\
0,\
0,\
0
booster/interlock/bst_bts2.1/StatRF->positions: "booster/interlock/plc_int/db_50[1071]",\
"booster/interlock/plc_int/db_50[1070]",\
"booster/interlock/plc_int/db_50[1]",\
"booster/interlock/plc_int/db_50[10]",\
"booster/interlock/plc_int/db_50[1]",\
"booster/interlock/plc_int/db_50[1]",\
"booster/interlock/plc_int/db_50[1]",\
"booster/interlock/plc_int/db_50[1]"
booster/interlock/bst_bts2.1/ValveStat->comments: "133.7 - Beam stopper 2.1 aperto",\
"133.6 - Beam stopper 2.1 chiuso",\
"133.5 - PRS_BST2.1",\
"152.4 - ABI_OPN_BST2_1",\
"0.0 - unused",\
"152.5 - Errore apertura beam stopper BST_2_1",\
"152.6 - Errore chiusira beam stopper BST_2_1",\
"152.7 - MEMCONT_BST_BTS2_1"
booster/interlock/bst_bts2.1/ValveStat->labels: FCA_BST2_1_da_acc,\
FCC_BST2_1_da_acc,\
PRS_BST2.1,\
ABI_OPN_BST2_1,\
unused,\
ERROROPEN_BST_BTS2_1,\
ERRORCLOSE_BST_BTS2_1_1,\
MEMCONT_BST_BTS2_1
booster/interlock/bst_bts2.1/ValveStat->positions: "booster/interlock/plc_int/db_50[1071]",\
"booster/interlock/plc_int/db_50[1070]",\
"booster/interlock/plc_int/db_50[1069]",\
"booster/interlock/plc_int/db_50[1220]",\
"booster/interlock/plc_int/db_50[0]",\
"booster/interlock/plc_int/db_50[1221]",\
"booster/interlock/plc_int/db_50[1222]",\
"booster/interlock/plc_int/db_50[1223]"
#---------------------------------------------------------
# CLASS AccessConf properties
#---------------------------------------------------------
CLASS/AccessConf->cvs_location: "/home/cvsadm/cvsroot/fermi/servers/accessconf/src/"
CLASS/AccessConf->cvs_tag: release_12
CLASS/AccessConf->Description: ""
CLASS/AccessConf->doc_url: "http://www.esrf.eu/computing/cs/tango/tango_doc/ds_doc/"
CLASS/AccessConf->InheritedFrom: Device_Impl
CLASS/AccessConf->ProjectTitle: "Storage Ring Access"
# CLASS AccessConf attribute properties
# --- dserver/accessconf-srv/booster properties
dserver/accessconf-srv/booster->polling_threads_pool_conf: "booster/interlock/bst_bts2.1"
dserver/accessconf-srv/booster->__SubDevices: "tango://tom.ecs.elettra.trieste.it:20000/dserver/plcinterlock-srv/booster"
#
# Resource backup , created Fri May 22 14:09:41 CEST 2020
#
#---------------------------------------------------------
# SERVER accessconf-srv/psabi, AccessConf device declaration
#---------------------------------------------------------
access-conf-srv/psabi/DEVICE/AccessConf: "sr/power_supply/psabi_sr"
# --- sr/power_supply/psabi_sr properties
sr/power_supply/psabi_sr->Attr_config_file: ""
sr/power_supply/psabi_sr->Attr_config_prop: #,\
"#attr:Plc_status:0:state:0:plc_state:check if low level server state = ON",\
#,\
"attr:ABI_GEN_PS:0:db20:89.1:remote_PWR_ABI_ON_FDBK:Abilitazione PWR supply da comando remoto ricevuta",\
"attr:ABI_S1_PS:0:db20:104.0:REM_PWR_ABI_ON_S1_OK:feedback abilitazione PWR supply sezione 1 OK",\
"attr:ABI_S2_PS:0:db20:104.1:REM_PWR_ABI_ON_S2_OK:feedback abilitazione PWR supply sezione 2 OK",\
"attr:ABI_S3_PS:0:db20:104.2:REM_PWR_ABI_ON_S3_OK:feedback abilitazione PWR supply sezione 3 OK",\
"attr:ABI_S4_PS:0:db20:104.3:REM_PWR_ABI_ON_S4_OK:feedback abilitazione PWR supply sezione 4 OK",\
"attr:ABI_S5_PS:0:db20:104.4:REM_PWR_ABI_ON_S5_OK:feedback abilitazione PWR supply sezione 5 OK",\
"attr:ABI_S6_PS:0:db20:104.5:REM_PWR_ABI_ON_S6_OK:feedback abilitazione PWR supply sezione 6 OK",\
"attr:ABI_S7_PS:0:db20:104.6:REM_PWR_ABI_ON_S7_OK:feedback abilitazione PWR supply sezione 7 OK",\
"attr:ABI_S8_PS:0:db20:104.7:REM_PWR_ABI_ON_S8_OK:feedback abilitazione PWR supply sezione 8 OK",\
"attr:ABI_S9_PS:0:db20:105.0:REM_PWR_ABI_ON_S9_OK:feedback abilitazione PWR supply sezione 9 OK",\
"attr:ABI_S10_PS:0:db20:105.1:REM_PWR_ABI_ON_S10_OK:feedback abilitazione PWR supply sezione 10 OK",\
"attr:ABI_S11_PS:0:db20:105.2:REM_PWR_ABI_ON_S11_OK:feedback abilitazione PWR supply sezione 11 OK",\
"attr:ABI_S12_PS:0:db20:105.3:REM_PWR_ABI_ON_S12_OK:feedback abilitazione PWR supply sezione 12 OK",\
"attr:ABI_BTS_PS:0:db20:105.4:REM_PWR_ABI_ON_BTS_OK:feedback abilitazione PWR supply sezione BTS OK",\
#,\
cmd:enable_gen_ps:Send_cmd:103:11.7,\
cmd:disable_gen_ps:Send_cmd:103:11.6,\
cmd:enable_s1_ps:Send_cmd:103:68.1,\
cmd:disable_s1_ps:Send_cmd:103:68.0,\
cmd:enable_s2_ps:Send_cmd:103:68.3,\
cmd:disable_s2_ps:Send_cmd:103:68.2,\
cmd:enable_s3_ps:Send_cmd:103:68.5,\
cmd:disable_s3_ps:Send_cmd:103:68.4,\
cmd:enable_s4_ps:Send_cmd:103:68.7,\
cmd:disable_s4_ps:Send_cmd:103:68.6,\
cmd:enable_s5_ps:Send_cmd:103:69.1,\
cmd:disable_s5_ps:Send_cmd:103:69.0,\
cmd:enable_s6_ps:Send_cmd:103:69.3,\
cmd:disable_s6_ps:Send_cmd:103:69.2,\
cmd:enable_s7_ps:Send_cmd:103:69.5,\
cmd:disable_s7_ps:Send_cmd:103:69.4,\
cmd:enable_s8_ps:Send_cmd:103:69.7,\
cmd:disable_s8_ps:Send_cmd:103:69.6,\
cmd:enable_s9_ps:Send_cmd:103:70.1,\
cmd:disable_s9_ps:Send_cmd:103:70.0,\
cmd:enable_s10_ps:Send_cmd:103:70.3,\
cmd:disable_s10_ps:Send_cmd:103:70.2,\
cmd:enable_s11_ps:Send_cmd:103:70.5,\
cmd:disable_s11_ps:Send_cmd:103:70.4,\
cmd:enable_s12_ps:Send_cmd:103:70.7,\
cmd:disable_s12_ps:Send_cmd:103:70.6,\
cmd:enable_bts_ps:Send_cmd:103:71.1,\
cmd:disable_bts_ps:Send_cmd:103:71.0,\
#
sr/power_supply/psabi_sr->Low_level_srv: "tom:20000/sr/interlock/plc_int"
sr/power_supply/psabi_sr->__SubDevices: "sr/interlock/plc_int",\
"dserver/plcint-e-srv/sr"
# --- sr/power_supply/psabi_sr attribute properties
sr/power_supply/psabi_sr/ABI_BTS_PS->comments: "105.4 - feedback abilitazione PWR supply sezione BTS OK"
sr/power_supply/psabi_sr/ABI_BTS_PS->labels: REM_PWR_ABI_ON_BTS_OK
sr/power_supply/psabi_sr/ABI_BTS_PS->positions: "sr/interlock/plc_int/db20[844]"
sr/power_supply/psabi_sr/ABI_GEN_PS->comments: "89.1 - Abilitazione PWR supply da comando remoto ricevuta"
sr/power_supply/psabi_sr/ABI_GEN_PS->labels: remote_PWR_ABI_ON_FDBK
sr/power_supply/psabi_sr/ABI_GEN_PS->positions: "sr/interlock/plc_int/db20[713]"
sr/power_supply/psabi_sr/ABI_S10_PS->comments: "105.1 - feedback abilitazione PWR supply sezione 10 OK"
sr/power_supply/psabi_sr/ABI_S10_PS->labels: REM_PWR_ABI_ON_S10_OK
sr/power_supply/psabi_sr/ABI_S10_PS->positions: "sr/interlock/plc_int/db20[841]"
sr/power_supply/psabi_sr/ABI_S11_PS->comments: "105.2 - feedback abilitazione PWR supply sezione 11 OK"
sr/power_supply/psabi_sr/ABI_S11_PS->labels: REM_PWR_ABI_ON_S11_OK
sr/power_supply/psabi_sr/ABI_S11_PS->positions: "sr/interlock/plc_int/db20[842]"
sr/power_supply/psabi_sr/ABI_S12_PS->comments: "105.3 - feedback abilitazione PWR supply sezione 12 OK"
sr/power_supply/psabi_sr/ABI_S12_PS->labels: REM_PWR_ABI_ON_S12_OK
sr/power_supply/psabi_sr/ABI_S12_PS->positions: "sr/interlock/plc_int/db20[843]"
sr/power_supply/psabi_sr/ABI_S1_PS->comments: "104.0 - feedback abilitazione PWR supply sezione 1 OK"
sr/power_supply/psabi_sr/ABI_S1_PS->labels: REM_PWR_ABI_ON_S1_OK
sr/power_supply/psabi_sr/ABI_S1_PS->positions: "sr/interlock/plc_int/db20[832]"
sr/power_supply/psabi_sr/ABI_S2_PS->comments: "104.1 - feedback abilitazione PWR supply sezione 2 OK"
sr/power_supply/psabi_sr/ABI_S2_PS->labels: REM_PWR_ABI_ON_S2_OK
sr/power_supply/psabi_sr/ABI_S2_PS->positions: "sr/interlock/plc_int/db20[833]"
sr/power_supply/psabi_sr/ABI_S3_PS->comments: "104.2 - feedback abilitazione PWR supply sezione 3 OK"
sr/power_supply/psabi_sr/ABI_S3_PS->labels: REM_PWR_ABI_ON_S3_OK
sr/power_supply/psabi_sr/ABI_S3_PS->positions: "sr/interlock/plc_int/db20[834]"
sr/power_supply/psabi_sr/ABI_S4_PS->comments: "104.3 - feedback abilitazione PWR supply sezione 4 OK"
sr/power_supply/psabi_sr/ABI_S4_PS->labels: REM_PWR_ABI_ON_S4_OK
sr/power_supply/psabi_sr/ABI_S4_PS->positions: "sr/interlock/plc_int/db20[835]"
sr/power_supply/psabi_sr/ABI_S5_PS->comments: "104.4 - feedback abilitazione PWR supply sezione 5 OK"
sr/power_supply/psabi_sr/ABI_S5_PS->labels: REM_PWR_ABI_ON_S5_OK
sr/power_supply/psabi_sr/ABI_S5_PS->positions: "sr/interlock/plc_int/db20[836]"
sr/power_supply/psabi_sr/ABI_S6_PS->comments: "104.5 - feedback abilitazione PWR supply sezione 6 OK"
sr/power_supply/psabi_sr/ABI_S6_PS->labels: REM_PWR_ABI_ON_S6_OK
sr/power_supply/psabi_sr/ABI_S6_PS->positions: "sr/interlock/plc_int/db20[837]"
sr/power_supply/psabi_sr/ABI_S7_PS->comments: "104.6 - feedback abilitazione PWR supply sezione 7 OK"
sr/power_supply/psabi_sr/ABI_S7_PS->labels: REM_PWR_ABI_ON_S7_OK
sr/power_supply/psabi_sr/ABI_S7_PS->positions: "sr/interlock/plc_int/db20[838]"
sr/power_supply/psabi_sr/ABI_S8_PS->comments: "104.7 - feedback abilitazione PWR supply sezione 8 OK"
sr/power_supply/psabi_sr/ABI_S8_PS->labels: REM_PWR_ABI_ON_S8_OK
sr/power_supply/psabi_sr/ABI_S8_PS->positions: "sr/interlock/plc_int/db20[839]"
sr/power_supply/psabi_sr/ABI_S9_PS->comments: "105.0 - feedback abilitazione PWR supply sezione 9 OK"
sr/power_supply/psabi_sr/ABI_S9_PS->labels: REM_PWR_ABI_ON_S9_OK
sr/power_supply/psabi_sr/ABI_S9_PS->positions: "sr/interlock/plc_int/db20[840]"
#---------------------------------------------------------
# CLASS AccessConf properties
#---------------------------------------------------------
CLASS/AccessConf->cvs_location: "/home/cvsadm/cvsroot/fermi/servers/accessconf/src/"
CLASS/AccessConf->cvs_tag: release_12
CLASS/AccessConf->Description: ""
CLASS/AccessConf->doc_url: "http://www.esrf.eu/computing/cs/tango/tango_doc/ds_doc/"
CLASS/AccessConf->InheritedFrom: Device_Impl
CLASS/AccessConf->ProjectTitle: "Storage Ring Access"
# CLASS AccessConf attribute properties
# --- dserver/accessconf-srv/psabi properties
dserver/accessconf-srv/psabi->__SubDevices: "tango://tom.ecs.elettra.trieste.it:20000/dserver/plcint-e-srv/sr"
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment